Your region and language were selected automatically. You can change this at any time in the menu on the site.
Americas | Español

Medición de cxolor con patrón digital

Article No. 7085

spectro2go 45/0
Espectrofotometro portatil con tolerancia ajustada 45/0

  • Geometría Color: 45º c:0º,
  • Geometría Brillo: 60°

More options

Color Geometry
Sample Port
Click here for the Chinese price list in RMB
$13,750.00 €11,300.00 excl. taxes & shipping cost

Features

Controlling color harmony of multi-component products within a global supply chain is a challenge. The outstanding technical performance of the spectro2go allows the use of digital standards. Thus, everybody aims for the same color and 60° gloss target.

  • Color and 60° gloss measurement in one
  • Exchange of digital standards due to excellent inter-instrument agreement
  • Balanced and upfront design with large color touchscreen
  • External checking and calibration standards
  • Live preview of the measurement spot with integrated camera
  • Smart high-tech LED illumination for excellent short-term, long-term and temperature stability
  • 10 year warranty on LED light source - no lamp change needed
  • Professional data analysis with smart-chart combined with WiFi or USB data transfer

Technical Attributes

    Technical Properties

  • Measuring Capability
    Color, Gloss
  • Color Measurement

  • Geometría de color
    45°c:0°
  • Puerto de muestra
    12 mm
  • Área de medida
    8 mm
  • Rango espectral
    400 - 700 nm, resolutión 10 nm
  • Rango de medición
    0 - 170% remission
  • Repetibilidad
    0.01 ΔE94 (10 medidas consecutivas sobre el patrón blanco)
  • Reproducibilidad
    0.1 ΔE94 (promedio en 12 patrones BCRA II)
  • Sistema de color
    CIELab/Ch, Lab(h), XYZ; Yxy
  • Diferencias de color
    ΔE*; ΔE(h); ΔECMC; ΔE94; ΔE99; ΔE2000; E2000 PF; ΔE DIN6175-2019
  • Índices
    YIE313, YID1925, WIE313, CIE, Berger, La intensidad del color, opacidad; metamerismo
  • Iluminantes
    A, C, D50, D55, D65, D75, F2, F6, F7, F8, F10, F11, UL30, CIE 015:2018 LED Illuminants
  • Observador
    2°, 10°
  • Gloss Measurement

  • Repeatability Gloss 0-20

    ± 0.1 GU

  • Repeatability Gloss 20-100

    ± 0.2 GU

  • Reproducibility Gloss 0-20

    ± 0.5 GU

  • Reproducibility Gloss 20-100

    ± 1.0 GU

  • Geometría de brillo
    60°
  • Abertura de brillo
    5 x 10 mm
  • Rango de medición
    0 - 100 GU
  • Repetibilidad

    0-20 GU:     ± 0.1 GU

    20-100 GU: ± 0.2 GU

  • Reproducibilidad

    0-20 GU:     ± 0.2 GU
    20-100 GU: ± 1.0 GU

  • General

  • Memoria
    4.000 patrones y 10.000 muestras
  • Interfaz
    Porto USB
  • Pantalla
    Pantalla táctil a color de 3.5 pulgadas
  • Idiomas
    Inglés Alemán Francés Italiano Español Russian Japonés Chinese
  • Alimentación
    Batería interna recargable
  • Alimentación
    100 - 240 V, 50/60 Hz
  • Batería
    7.2 V, 2350 mAh, 16.92 Wh
  • Capacidad de la batería
    1200 lecturas
  • Peso
    0.7 kg
  • Peso
    1.5 lb
  • Temperatura de operación
    10 - 40 °C
  • Temperatura de almacenaje
    0 - 60 °C
  • Temperatura de operación
    50 - 104 °F
  • Temperatura de almacenaje
    32 - 140 °F
  • Humedad relativa
    hast 85 % no condensada en 35 °C (95 °F)
  • Dimensiones L x W x H
    8.7 x 11 x 18.8 cm
  • Dimensiones L x W x H
    3.4 x 4.3 x 7.4 in

Standards

DIN EN ISO

11664

ISO

2813 7668

ASTM

D2244 E308 E1164 D523 D2457

DIN

5033 5036 6174 67530

Delivery Content

Spectrophotometer
White calibration standard
Color and gloss checking standard
Certificate
Software with two licensees for download:
smart-lab Color (7083) or smart-process Color (7084)
USB online cable type C/A for data transfer (7078)
External power supply (type A/C/G/I) (7305)
Stylus (7079)
Protective cap (7076), hand strap
Manual
Carrying case
1-day training

Knowledge

The basic building blocks of color measurement

Visual color perception is influenced by our individual color preferences, which are dependent on personal factors (mood, age, gender etc.), environment (lighting, surrounding etc.) as well as our ability to communicate color and color differences. A color looks different in the department store (cool white fluorescent lighting) than at home (warm, incandescent lighting). In order to guarantee consistent color and appearance under all possible circumstances, it is essential to standardize light source, observer and understand the spectral remission data of the object. This information will be the basis for calculation of colorimetric data as it is used for color communication and color QC in production.

Read more

Color Difference Equations for Solid Colors

It is now almost 100 years since, in 1931, the CIE Yxy chromaticity color space was defined by the “International Commission on Illumination (CIE)”. To overcome its limitations of not being uniform, the CIE recommended two alternate color spaces since then: CIELAB (or CIE 1976 L*a*b*) and CIELUV (or CIE L*u*v*). They are based on the opponent color theory of color vision, which says that two colors cannot be both green and red at the same time, nor blue and yellow at the same time. During the last years developments of new color difference equations and color spaces were carried out. Their goal was to improve the correlation between visual perception and instrumentally measured values. Additionally, they wanted to permit the use of a single number tolerance for all colors.

Read more
Subscribe to our Newsletter and stay informed! subscribe
CANCEL